Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 311: 123974, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38377639

RESUMO

Fish epidermal mucus is an important reservoir of antipathogenic compounds which serves as the first line of the immune defence. Despite its significant role in the physiology and health of fish, detailed profiling of fish epidermal mucus has yet to be explored. Therefore, this study investigates a label-free colloidal surface-enhanced Raman spectroscopic (SERS) method for profiling grouper mucus. Gold nanoparticles were first synthesised using the standard citrate reduction and characterised using ultraviolet-visible spectroscopy, transmission electron microscopy and dynamic light scattering. The influence of acidified sodium sulphate (Na2SO4) at pH 3 as the aggregating agent on the enhancement of the SERS spectrum of different analyte samples including rhodamine 6G (R6G) dye, lysozyme solution and hybrid grouper (Epinephelus fuscoguttatus × Epinephelus lanceolatus) mucus was observed. Based on the results, an optimal Na2SO4 concentration of 1 M was recorded to achieve the highest enhancement of the SERS signal for R6G and grouper mucus, while the optimal concentration for lysozyme was 0.1 M. The results indicated a higher degree of aggregation induced by lysozyme than R6G and grouper mucus. A few overlapping peaks of the SERS spectra of lysozyme and grouper mucus made it possible to confirm the presence of lysozyme as potential biomarkers.


Assuntos
Bass , Nanopartículas Metálicas , Sulfatos , Animais , Nanopartículas Metálicas/química , Muramidase , Ouro/química , Análise Espectral Raman/métodos
2.
Polymers (Basel) ; 15(9)2023 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-37177306

RESUMO

This study aimed to prepare silicone rubber composites with heavy metal oxide nanoparticles for gamma ray shielding applications. Different heavy metal oxide nanoparticles were incorporated into the silicone rubber matrix, and the prepared composites were characterized for their thermal, mechanical, and radiation shielding properties. The density of the prepared SR samples ranged from 1.25 to 2.611 g·cm-3, with SR-2 having the highest density due to the presence of lead oxide. Additionally, the thermal stability of the materials improved with the addition of HMO nanoparticles, as indicated by TGA results. The prepared SR materials showed ultimate deformation displacement ranging from 14.17 to 21.23 mm, with the highest value recorded for SR-3 and the lowest for SR-2. We investigated the transmission factor (TF) of gamma rays through silicone rubber (SR) composites with different heavy metal oxide (HMO) nanoparticles. The addition of HMOs resulted in a decrease in TF values, indicating improved radiation shielding performance. The TF was found to be lowest in SR-5, which contained 15% of Bi2O3, WO3, BaO, and Zr2O3 each. The linear attenuation coefficient (LAC) of the SR samples was also evaluated, and it was found that the incorporation of HMOs increased the probability of photon interactions, leading to improved radiation protection effectiveness. The half-value layer (HVL) of the SR samples was also examined, and it was found that the addition of HMOs resulted in a significant reduction in HVL values, particularly at low energy levels. SR-5 had the lowest HVL among the group, while SR-2, SR-3, and SR-4 had higher HVL values. These results demonstrate the effectiveness of using HMOs in enhancing the radiation shielding properties of SR composites, particularly for low-energy gamma rays.

3.
Materials (Basel) ; 16(8)2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37110089

RESUMO

This study aimed to develop a mortar composite with improved gamma ray shielding properties using WO3 and Bi2O3 nanoparticles, as well as granite residue as a partial replacement of sand. The physical properties and effects of sand substitution and nanoparticle addition on the mortar composite were analyzed. TEM analysis confirmed the size of Bi2O3 and WO3 NPs to be 40 ± 5 nm and 35 ± 2 nm, respectively. SEM images showed that increasing the percentage of granite residues and nanoparticles improved the homogeneity of the mixture and decreased the percentage of voids. TGA analysis indicated that the thermal properties of the material improved with the increase in nanoparticles, without decreasing the material weight at higher temperatures. The linear attenuation coefficients were reported and we found that the LAC value at 0.06 MeV increases by a factor of 2.47 when adding Bi2O3, while it is enhanced by a factor of 1.12 at 0.662 MeV. From the LAC data, the incorporation of Bi2O3 nanoparticles can greatly affect the LAC at low energies, and still have a small but noticeable effect at higher energies. The addition of Bi2O3 nanoparticles into the mortars led to a decrease in the half value layer, resulting in excellent shielding properties against gamma rays. The mean free path of the mortars was found to increase with increasing photon energy, but the addition of Bi2O3 led to a decrease in MFP and better attenuation, making the CGN-20 mortar the most ideal in terms of shielding ability among the prepared mortars. Our findings on the improved gamma ray shielding properties of the developed mortar composite have promising implications for radiation shielding applications and granite waste recycling.

4.
Biosensors (Basel) ; 13(2)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36832036

RESUMO

Biosensors are central to diagnostic and medicinal applications, especially in terms of monitoring, managing illness, and public health. Microfiber-based biosensors are known to be capable of measuring both the presence and behavior of biological molecules in a highly sensitive manner. In addition, the flexibility of microfiber in supporting a variety of sensing layer designs and the integration of nanomaterials with biorecognition molecules brings immense opportunity for specificity enhancement. This review paper aims to discuss and explore different microfiber configurations by highlighting their fundamental concepts, fabrication processes, and performance as biosensors.


Assuntos
Técnicas Biossensoriais , Nanoestruturas
5.
Materials (Basel) ; 15(22)2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36431654

RESUMO

Gaseous pollutants such as hydrogen gas (H2) are emitted in daily human activities. They have been massively studied owing to their high explosivity and widespread usage in many domains. The current research is designed to analyse optical fiber-based H2 gas sensors by incorporating palladium/graphene oxide (Pd/GO) nanocomposite coating as sensing layers. The fabricated multimode silica fiber (MMF) sensors were used as a transducing platform. The tapering process is essential to improve the sensitivity to the environment through the interaction of the evanescent field over the area of the tapered surface area. Several characterization methods including FESEM, EDX, AFM, and XRD were adopted to examine the structure properties of the materials and achieve more understandable facts about their functional performance of the optical sensor. Characterisation results demonstrated structures with a higher surface for analyte gas reaction to the optical sensor performance. Results indicated an observed increment in the Pd/GO nanocomposite-based sensor responses subjected to the H2 concentrations increased from 0.125% to 2.00%. The achieved sensitivities were 33.22/vol% with a response time of 48 s and recovery time of 7 min. The developed optical fiber sensors achieved excellent selectivity and stability toward H2 gas upon exposure to other gases such as ammonia and methane.

6.
Sensors (Basel) ; 21(21)2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34770602

RESUMO

The color of transformer oil can be one of the first indicators determining the quality of the transformer oil and the condition of the power transformer. The current method of determining the color index (CI) of transformer oil utilizes a color comparator based on the American Society for Testing and Materials (ASTM) D1500 standard, which requires a human observer, leading to human error and a limited number of samples tested per day. This paper reports on the utilization of ultra violet-blue laser at 405- and 450-nm wavelengths to measure the CI of transformer oil. In total, 20 transformer oil samples with CI ranging from 0.5 to 7.5 were measured at optical pathlengths of 10 and 1 mm. A linear regression model was developed to determine the color index of the transformer oil. The equation was validated and verified by measuring the output power of a new batch of transformer oil samples. Data obtained from the measurements were able to quantify the CI accurately with root-mean-square errors (RMSEs) of 0.2229 for 405 nm and 0.4129 for 450 nm. This approach shows the commercialization potential of a low-cost portable device that can be used on-site for the monitoring of power transformers.


Assuntos
Fontes de Energia Elétrica , Lasers , Humanos
7.
Sensors (Basel) ; 21(20)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34696079

RESUMO

For most natural or naturally-derived liquid products, their color reflects on their quality and occasionally affects customer preferences. To date, there are a few subjective and objective methods for color measurement which are currently utilized by various industries. Researchers are also improving these methods and inventing new methods, as color is proven to have the ability to provide various information on the condition and quality of the liquid. However, a review on the methods, especially for amber-colored liquid, has not been conducted yet. This paper presents a comprehensive review on the subjective and objective methods for color measurement of amber-colored liquids. The pros and cons of the measurement methods, the effects of the color on customer preferences, and the international industry standards on color measurements are reviewed and discussed. In addition, this study elaborates on the issues and challenges related to the color measurement techniques as well as recommendations for future research. This review demonstrates that the existing color measurement technique can determine the color according to the standards and color scales. However, the efforts toward minimizing the complexity of the hardware while maximizing the signal processing through advanced computation are still lacking. Therefore, through this critical review, this review can hopefully intensify the efforts toward finding an optimized method or technique for color measurement of liquids and thus expedite the development of a portable device that can measure color accurately.


Assuntos
Padrões de Referência , Cor , Previsões
8.
Polymers (Basel) ; 13(5)2021 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33671059

RESUMO

This paper proposes a novel idea to enhance the sensitivity and selectivity of surface plasmon resonance (SPR) optical sensor for detection of dengue virus type-2 envelope proteins (DENV-2 E-proteins) using polyamidoamine (PAMAM) dendrimer biopolymer-based nanocomposite thin film. For this purpose, two ranges of DENV-2 E-protein concentrations, i.e., 0.000008-0.0001 nM and 0.00008-0.005 nM were evaluated, and the lowest detectable concentration was achieved at 0.00008 nM. The incorporation of PAMAM dendrimer-based nanocomposite thin film with an SPR sensor exhibited a significant increase in sensitivity and binding affinity to a lower range DENV-2 E-protein concentrations. Moreover, the proposed sensor displayed good selectivity towards DENV-2 E-proteins and have an average recovery of 80-120%. The findings of this study demonstrated that PAMAM dendrimer-based nanocomposite thin film combined with SPR sensor is a promising diagnostic tool for sensitive and selective detection of DENV-2 E-proteins.

9.
Sensors (Basel) ; 21(2)2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-33466822

RESUMO

Ammonia detection in ambient air is critical, given its implication on the environment and human health. In this work, an optical fiber tapered to a 20 µm diameter and coated with graphene oxide was developed for absorbance response monitoring of ammonia at visible (500-700 nm) and near-infrared wavelength regions (700-900 nm). The morphology, surface characteristics, and chemical composition of the graphene oxide samples were confirmed by a field emission scanning electron microscope, an atomic force microscope, X-ray diffraction, and an energy dispersion X-ray. The sensing performance of the graphene oxide-coated optical microfiber sensor towards ammonia at room temperature revealed better absorbance response at the near-infrared wavelength region compared to the visible region. The sensitivity, response and recovery times at the near-infrared wavelength region were 61.78 AU/%, 385 s, and 288 s, respectively. The sensitivity, response and recovery times at the visible wavelength region were 26.99 AU/%, 497 s, and 192 s, respectively. The selectivity of the sensor towards ammonia was affirmed with no response towards other gases.

10.
Sensors (Basel) ; 20(17)2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32825539

RESUMO

The need for environmental protection and water pollution control has led to the development of different sensors for determining many kinds of pollutants in water. Ammonia nitrogen presence is an important indicator of water quality in environmental monitoring applications. In this paper, a high sensitivity sensor for monitoring ammonia nitrogen concentration in water using a tapered microfiber interferometer (MFI) as a sensor platform and a broad supercontinuum laser as the light source is realized. The MFI is fabricated to the waist diameter of 8 µm producing a strong interference pattern due to the coupling of the fundamental mode with the cladding mode. The MFI sensor is investigated for a low concentration of ammonia nitrogen in water in the wide wavelength range from 1500-1800 nm with a high-power signal provided by the supercontinuum source. The broad source allows optical sensing characteristics of the MFI to be evaluated at four different wavelengths (1505, 1605, 1705, and 1785 nm) upon exposure towards various ammonia nitrogen concentrations. The highest sensitivity of 0.099 nm/ppm that indicates the wavelength shift is observed at 1785 nm operating wavelength. The response is linear in the ammonia nitrogen range of 5-30 ppm with the best measurement resolution calculated to be 0.5 ppm. The low concentration ammonia nitrogen detected by the MFI in the unique infrared region reveals the potential application of this optical fiber-based sensor for rivers and drinking water monitoring.

11.
Sci Rep ; 10(1): 11710, 2020 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-32678157

RESUMO

A versatile synthetic approach for development of highly fluorescent nitrogen-doped carbon dots (N-CDs) from carboxymethylcellulose in the presence of linear polyethyleneimine (LPEI) has been developed. According to single factor method, central composite design incorporated with response surface methodology matrix was applied to find and model optimal conditions for the temperature (220-260 °C), duration (1-3 h) and LPEI weight (0.5-1.5%). The statistical results show that duration was the most significant parameter for efficient carbonization conversion rate in comparison with temperature and LPEI weight. The reduced cubic model (R2 = 0.9993) shows a good correlation between the experimental data and predicted values. The optimal variables were temperature of 260 °C, duration of 2 h and LPEI weight of 1%. Under these conditions, quantum yield of up to 44% was obtained. The numerically optimized N-CDs have an average size of 3.4 nm with graphitic nature owing to the abundant amino species incorporated into the carbon core framework. The blue-green N-CDs possess emission dependent upon the solvent polarity, wide pH stability with enhanced emission in an acidic environment. Impressively, the N-CDs show long-shelf-life for up to 1 year with no noticeable precipitation. The N-CDs were able to recognize a high concentration of Fe3+ ions with a detection limit of 0.14 µM in acidic solution owing to the special coordination for Fe3+ to be captured by electron-donating oxygen/ amino groups around N-CDs. Moreover, the N-CDs can also be used as a new kind of fluorescent ink for imaging applications.

12.
Nanomaterials (Basel) ; 10(3)2020 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-32245185

RESUMO

Dengue viral infection is one of the most common deadliest diseases and has become a recurrent issue for public health in tropical countries. Although the spectrum of clinical diagnosis and treatment have recently been established, the efficient and rapid detection of dengue virus (DENV) during viremia and the early febrile phase is still a great challenge. In this study, a dithiobis (succinimidyl undecanoate, DSU)/amine-functionalized reduced graphene oxide--polyamidoamine dendrimer (DSU/amine-functionalized rGO-PAMAM) thin film-based surface plasmon resonance (SPR) sensor was developed for the detection of DENV 2 E-proteins. Different concentrations of DENV 2 E-proteins were successfully tested by the developed SPR sensor-based system. The performance of the developed sensor showed increased shift in the SPR angle, narrow full-width-half-maximum of the SPR curve, high detection accuracy, excellent figure of merit and signal-to-noise ratio, good sensitivity values in the range of 0.08-0.5 pM (S = 0.2576°/pM, R2 = 0.92), and a high equilibrium association constant (KA) of 7.6452 TM-1. The developed sensor also showed a sensitive and selective response towards DENV 2 E-proteins compared to DENV 1 E-proteins and ZIKV (Zika virus) E-proteins. Overall, it was concluded that the Au/DSU/amine-functionalized rGO-PAMAM thin film-based SPR sensor has potential to serve as a rapid clinical diagnostic tool for DENV infection.

13.
Appl Spectrosc ; 74(12): 1452-1462, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32166979

RESUMO

In this work, principal component analysis (PCA) was utilized to analyze laser-induced breakdown spectroscopy (LIBS) signals of the extracted chicken fat, lamb fat, beef fat, and lard froze using two different freezing methods. The frozen samples were ablated using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser with a wavelength of 1064 nm, 170 mJ pulse energy, and 6 ns pulse duration to produce plasma on target surfaces. The samples were ablated using 30-60 shots of the laser beam at different spots. Stronger LIBS signals from the extracted chicken fat and lamb fat were obtained with liquid nitrogen (LN2) method. However, LIBS signals obtained from the freezer freezing method were found to be stronger for extracted beef fat and lard. The PCA was then used to visualize the LIBS spectra of extracted animal fats into a score plot. Data points of each extracted animal fat were divided into three groups representing LIBS spectra collected at the early, middle, and end part of the ablation process. The score plot revealed that the data points of the three groups of frozen extracted animal fats using the LN2 method were more closely clustered than those frozen in the freezer. Good discrimination with 97% of the variance was achieved between the extracted chicken fat, lamb fat, beef fat, and lard using the LN2 method in the three-dimensional score plot. LIBS signals of the extracted animal fats produced from the LN2 method were found to be more stable than those from the freezer method.


Assuntos
Gorduras na Dieta/análise , Análise Espectral/métodos , Alumínio/química , Animais , Bovinos , Galinhas , Contaminação de Alimentos/prevenção & controle , Congelamento , Análise de Componente Principal , Ovinos , Ítrio/química
14.
Sci Rep ; 10(1): 2374, 2020 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-32047209

RESUMO

In this work, sensitive detection of dengue virus type 2 E-proteins (DENV-2 E-proteins) was performed in the range of 0.08 pM to 0.5 pM. The successful DENV detection at very low concentration is a matter of concern for targeting the early detection after the onset of dengue symptoms. Here, we developed a SPR sensor based on self-assembled monolayer/reduced graphene oxide-polyamidoamine dendrimer (SAM/NH2rGO/PAMAM) thin film to detect DENV-2 E-proteins. Surface characterizations involving X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR) confirms the incorporation of NH2rGO-PAMAM nanoparticles in the prepared sensor films. The specificity, sensitivity, binding affinity, and selectivity of the SPR sensor were then evaluated. Results indicated that the variation of the sensing layer due to different spin speed, time incubation, and concentration provided a better interaction between the analyte and sensing layer. The linear dependence of the SPR sensor showed good linearity (R2 = 0.92) with the lowest detection of 0.08 pM DENV-2 E-proteins. By using the Langmuir model, the equilibrium association constant was obtained at very high value of 6.6844 TM-1 (R2 = 0.99). High selectivity of the SPR sensor towards DENV-2 E-proteins was achieved in the presence of other competitors.


Assuntos
Dendrímeros/química , Grafite/química , Ressonância de Plasmônio de Superfície/métodos , Proteínas do Envelope Viral/química , Nanopartículas/química , Sensibilidade e Especificidade , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Proteínas do Envelope Viral/análise , Difração de Raios X
15.
Sci Rep ; 9(1): 13483, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31530893

RESUMO

The exponential escalation of dengue cases has indeed become a global health crisis. This work elaborates on the development of a biofunctionalized tapered optical fiber (TOF) based sensor with the integration of polyamidoamine (PAMAM) dendrimer for the detection of dengue E protein. The dimension of the TOF generated an evanescent field that was sensitive to any changes in the external medium while the integration of PAMAM promoted more adhesion of bio-recognition molecules; anti-DENV II E protein antibodies; that were complementary to the targeted protein. This in return created more active sites for the absorption of DENV II E proteins onto the tapered region. The resolution and detection limit of the sensor are 19.53 nm/nM and 1 pM, respectively with Kd = 1.02 × 10-10 M.


Assuntos
Técnicas Biossensoriais , Dendrímeros , Dengue/diagnóstico , Fibras Ópticas , Bioengenharia , Dengue/virologia , Vírus da Dengue , Feminino , Humanos , Masculino , Microscopia de Força Atômica , Análise Espectral Raman , Proteínas Virais/análise
16.
Materials (Basel) ; 12(14)2019 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-31323741

RESUMO

The effect of NaOH solution on the formation of nanoparticles has been the subject of ongoing debate in selenium-based material research. In this project, the robust correlation between the mechanistic growth of zinc selenide/graphene oxide (ZnSe/GO) composite and the concentration of NaOH are elucidated. The ZnSe/GO composite was synthesized via microwave-assisted hydrothermal method and the concentrations of NaOH are controlled at 2 M, 3 M, 4 M, 5 M and 6 M. The XRD spectra show that the crystal phases of the samples exhibited a 100% purity of ZnSe when the concentration of sodium hydroxide (NaOH) was set at 4 M. The further increase of NaOH concentration leads to the formation of impurities. This result reflects the essential role of hydroxyl ions in modifying the purity state of ZnSe/GO composite. The optical band gap energy of ZnSe/GO composite also decreased from 2.68 eV to 2.64 eV when the concentration of NaOH increased from 2 M to 4 M. Therefore, it can be concluded that the optimum concentration of NaOH used in synthesizing ZnSe/GO composite is 4 M. This project provides an alternative green method in the formation of a high purity ZnSe/GO composite.

17.
RSC Adv ; 9(71): 41729-41736, 2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-35541586

RESUMO

Surface plasmon resonance (SPR) sensors as novel optical sensors for the detection of a variety of analytes have been receiving increasing attention and their sensitivity has become the research hotspot recently. In this study, the sensitivity of an SPR optical sensor was enhanced by modifying a gold thin film with a nanocrystalline cellulose (NCC)-based material for zinc ion (Zn2+) detection that exists in the environment due to industrial processing. By replacing the gold thin film with a novel modified-gold thin film, Zn2+ can be detected from the range of 0 to 10 ppm using SPR. It is believed that the Zn2+ may interact with the negative charge molecules that exist on the modified-gold thin film, and this was confirmed via X-ray photoelectron spectroscopy (XPS). Moreover, this modified-gold-SPR has a high sensitivity of 1.892° ppm-1 up to 0.1 ppm with an enhanced detection of Zn2+ as low as 0.01 ppm. The SPR results also followed the Langmuir isotherm model with a binding affinity of 1.927 × 103 M-1, which further confirmed the sensitivity of the SPR sensor. In addition, using the modified-gold thin film, SPR has a higher affinity towards Zn2+ compared to other metal ions, i.e. Ni2+, Fe2+, Cr2+, Mn2+, and Co2+.

18.
Sci Rep ; 8(1): 7399, 2018 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-29743664

RESUMO

Three-dimensional (3D) printing technology provides a novel approach to material fabrication for various applications because of its ability to create low-cost 3D printed platforms. In this study, a printable graphene-based conductive filament was employed to create a range of 3D printed electrodes (3DEs) using a commercial 3D printer. This printing technology provides a simplistic and low-cost approach, which eliminates the need for the ex-situ modification and post-treatment of the product. The conductive nature of the 3DEs provides numerous deposition platforms for electrochemical active nanomaterials such as graphene, polypyrrole, and cadmium sulfide, either through electrochemical or physical approaches. To provide proof-of-concept, these 3DEs were physiochemically and electrochemically evaluated and proficiently fabricated into a supercapacitor and photoelectrochemical sensor. The as-fabricated supercapacitor provided a good capacitance performance, with a specific capacitance of 98.37 Fg-1. In addition, these 3DEs were fabricated into a photoelectrochemical sensing platform. They had a photocurrent response that exceeded expectations (~724.1 µA) and a lower detection limit (0.05 µM) than an ITO/FTO glass electrode. By subsequently modifying the printing material and electrode architecture, this 3D printing approach could provide a facile and rapid manufacturing process for energy devices based on the conceptual design.

19.
Spectrochim Acta A Mol Biomol Spectrosc ; 191: 111-115, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29024848

RESUMO

In this study, the combination of novel valinomycin doped chitosan-graphene oxide (C-GO-V) thin film and surface plasmon resonance (SPR) system for potassium ion (K+) detection has been developed. The novel C-GO-V thin film was deposited on the gold surface using spin coating technique. The system was used to monitor SPR signal for K+ in solution with and without C-GO-V thin film. The K+ can be detected by measuring the SPR signal when C-GO-V thin film is exposed to K+ in solution. The sensor produces a linear response for K+ ion up to 100ppm with sensitivity and detection limit of 0.00948°ppm-1 and 0.001ppm, respectively. These results indicate that the C-GO-V film is high potential as a sensor element for K+ that has been proved by the SPR measurement.

20.
PLoS One ; 9(4): e93962, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24733263

RESUMO

Polypyrrole multi-walled carbon nanotube composite layers were used to modify the gold layer to measure heavy metal ions using the surface plasmon resonance technique. The new sensor was fabricated to detect trace amounts of mercury (Hg), lead (Pb), and iron (Fe) ions. In the present research, the sensitivity of a polypyrrole multi-walled carbon nanotube composite layer and a polypyrrole layer were compared. The application of polypyrrole multi-walled carbon nanotubes enhanced the sensitivity and accuracy of the sensor for detecting ions in an aqueous solution due to the binding of mercury, lead, and iron ions to the sensing layer. The Hg ion bonded to the sensing layer more strongly than did the Pb and Fe ions. The limitation of the sensor was calculated to be about 0.1 ppm, which produced an angle shift in the region of 0.3° to 0.6°.


Assuntos
Metais Pesados/análise , Nanotubos de Carbono/química , Polímeros/química , Pirróis/química , Ressonância de Plasmônio de Superfície/métodos , Adsorção , Íons , Ferro/análise , Chumbo/análise , Mercúrio/análise , Microscopia de Força Atômica , Fenômenos Ópticos , Refratometria , Soluções , Espectrofotometria Atômica , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...